MicroVue™ Complement Multiplex

ELISA based chemiluminescent multiplex for complement system analytes.


Product Specifications

 

Citations8
Specimen

Plasma, Serum

LLOQVaries
ULOQVaries
Assay Time3.5 Hours
Cross Reactivity

Rhesus Monkey, Cynomolgus Monkey 

Ordering Information

Intended Use: For research use only in the United States. Not for use in diagnostic procedures

Catalog Number

View Ordering Info tab for product options

Catalog Number (xUS)

View Ordering Info tab for product options

Size96 wells/test
Price (USD)

View Ordering Info tab for pricing

Price (EURO)

View Ordering Info tab for pricing

Contact us

US Phone+1 (858) 552 1100
EU Phone+353 (91) 412 474
US Emailcontact-us@quidelortho.com
EU Emailcontact-emea@quidelortho.com

Product description

 
An ELISA based assay designed to generate maximum data

The MicroVue Complement Multiplex is an ELISA based platform that allows for the measurement of up to 10 different complement system proteins. QuidelOrtho offers the following assay options (see the Ordering tab for more information):

How it works
ELISA within ELISA
  • Capture antibody is applied to 350-500 μm spots to bind target proteins.
  • Robotic liquid handlers deposit 20-50 nL of print diluent.
  • Static 96 well plate specially created to prevent inter-well signal loss.
Analyte Detection

Signal from individual spots is generated via standard biotin and streptavidin-HRP complexing. Chemiluminescent signal detection and intensity is then used to determine presence and quantity of the specific analytes.

For more information, view the MicroVue Complement Mulitplex brochure for full product specifications, performance review, technology overview, and more.

View our MicroVue Complement Multiplex advantages flyer for how the platform increase laboratory productivity.

Available analytes
Panel 1Panel 2
BaC1q
BbC2 intact
C2 intactC3 intact
C3aC3 intact
C3dC5 intact
C4aFactor D
C4dFactor P
C5a-
sC5b-9-
Factor D-
Factor H-
Factor I-
Why 2 Panels?

Complement proteins are found at different concentrations in the blood. Panel 1 analytes require a lower dilution factor (1:100) than those in Panel 2 (1:1000) for the multiplex to perform properly.

  • C2 Intact and Factor D can be utilized within both panels.
  • All other analytes must be utilized within their respective panels.
Compatability

A limited selection of analytes are not compatible for Panel 1

  • C3a is not compatible with C3d.
  • C4a is not compatible with C4d.

All Panel 2 analytes are compatible

Ordering info

Available analytes
Panel 1Ba, Bb, C2 Intact, C3a, C3d, C4a, C5a, sC5b-9, Factor D, Factor H, Factor I
Panel 2C1q, C2 Intact, C3 Intact, C4 Intact, C5 Intact, Factor D, Factor P
Why 2 Panels?Complement proteins are found at different concentrations in the blood. Panel 1 analytes require a lower dilution factor (1:100) than those in Panel 2 (1:1000) for the multiplex to perform properly. C2 Intact and Factor D can be utilized within both panels.
In-stock kits
CAT #DescriptionPrice (U.S. List)Price (Euro)Analytes
A900Complement Multiplex – Panel 1$5,565€5,080Ba, Bb, C3a, C4a, C5a, sC5b-9, FH, FI
A901Complement Multiplex – Panel 1 Focused$3,825€3,490Bb, C3a, C4a, C5a, sC5b-9
A916Complement Multiplex – Panel 2$5,030€4,590C1q, C2, C3, C4, C5, FD, FP
A917Complement Multiplex – Panel 2 Focused$3,060€2,795C1q, C3, C4, C5
 
Customized kits (a minium of 5 kits must be ordered)

 

Panel 1 - Customized Kits
CAT #DescriptionPrice (U.S. List)Price (Euro)Analytes
A903Custom 3-plex$2,295€2,095

Select from combinations of all Panel 1 analytes (see above).

 

Compatibility

A limited selection of analytes are not compatible for Panel 1

• C3a is not compatible with C3d

• C4a is not compatible with C4d

A904Custom 4-plex$3,060€2,795
A905Custom 5-plex$3,825€3,490
A906Custom 6-plex$4,450€4,065
A907Custom 7-plex$5,030€4,590
A908Custom 8-plex$5,565€5,080
A909Custom 9-plex$6,055€5,525
A910Custom 10-plex$6,490€5,925

 

Panel 2 - Customized Kits
CAT #DescriptionPrice (U.S. List)Price(Euro)Analytes
A918Custom 3-plex$2,295€2,095

Select from combinations of all Panel 2 analytes (see above).

All Panel 2 analytes are compatible.

A919Custom 4-plex$3,060€2,795
A920Custom 5-plex$3,825€3,490
A921Custom 6-plex$4,450€4,065

Specifications

Description

ELISA based chemiluminescent multiplex for complement sytsem analytes.

Size96 wells/test
Form

ELISA

SpecimenHuman: Plasma, Serum
Limit of Detection (LOD)Varies:  Refer to Product Instructions for individual analyte performance
Lower Limit of Quantitation (LLOQ)Varies:  Refer to Product Instructions for individual analyte performance
Upper Limit of Quantitation (ULOQ)Varies:  Refer to Product Instructions for individual analyte performance
Intra AssayVaries:  Refer to Product Instructions for individual analyte performance
Inter AssayVaries:  Refer to Product Instructions for individual analyte performance
Standards6
Controls2
Assay Time3.5 Hours
Cross Reactivity

Cynomolgus Monkey:  CSF, Serum, Vitreous
Humor Rhesus Monkey:  Serum
Contact Technical Services for additional information regarding cross-reactivity details

Storage2°C to 8°C until kit expiration
Background

The Complement System consists of more than 40 fluid and membrane-bound proteins and protein fragments organized into three primary pathways: Classical, Alternative, and Lectin . By a series of specific activation steps via either the classical, alternative, or the lectin pathway, the complement proteins mediate a set of activities ranging from the initiation of inflammation, clearance of immune complexes, disruption of cell membranes, and regulation of the immune response. Deficiencies in the complement cascade can predispose individuals to infection through ineffective opsonization or defects in the ability to lyse invading pathogens. Besides its essential role in maintaining health, the importance of the complement system in medicine lies in the fact that many acute and chronic diseases are associated with abnormalities in its function. Accordingly, quantitative analysis of different complement proteins and their activation by-products are of great practical importance in medical research.  There are numerous immunological methods for complement testing, including individual protein ELISA-based kits measuring complement cleavage products as markers of complement activation. However, the ability to measure multiple complement proteins in an individual sample constitutes a major step forward in research based tools.