Lyra® Parainfluenza Virus Assay
Lyra Assays
Lyra® Parainfluenza Virus Assay

The Lyra Parainfluenza Virus assay is a multiplex real-time PCR assay for the qualitative detection and identification of viral nucleic acids extracted from nasal swabs and nasopharyngeal swabs from symptomatic patients. The assay has been shown to detect and differentiate parainfluenza virus types 1, 2 and 3.

During the test, a multiplex RT-PCR reaction is carried out under optimized conditions in a single tube generating amplicons for each of the target viruses present in the sample. Identification of PIV-1, PIV-2, PIV-3 and the PRC occurs using target-specific primers and fluorescent-labeled probes that hybridize to conserved regions in the genomes of PIV-1, PIV-2, PIV-3 and the PRC.

The Lyra Parainfluenza Virus assay has a convenient, one-step reagent set up performed at room temperature on the bench top, without the need for ice or other cooling accessories. Moreover, optimized cycling conditions make results available in less than 75 minutes following extraction to aid in timely diagnosis and treatment. Lyra Parainfluenza Virus RT-PCR is available for use on the Applied Biosystems®  7500 Fast Dx Real-Time PCR Instrument.

The Lyra Parainfluenza Virus assay provides the flexibility to customize respiratory panels with other Lyra Real-Time PCR respiratory assays (Lyra Influenza A+B, Lyra hMPV+RSV, Lyra Adenovirus) that are run under the same cycling conditions to adapt to the shifting demands caused by variable local or seasonal disease prevalence. 

Please see chart below for ordering information.

Contact us

Lyra Assays
Lyra® Parainfluenza Virus Assay
Lyra® Parainfluenza Virus Assay

The Lyra Parainfluenza Virus assay is a multiplex real-time PCR assay for the qualitative detection and identification of viral nucleic acids extracted from nasal swabs and nasopharyngeal swabs from symptomatic patients. The assay has been shown to detect and differentiate parainfluenza virus types 1, 2 and 3.

During the test, a multiplex RT-PCR reaction is carried out under optimized conditions in a single tube generating amplicons for each of the target viruses present in the sample. Identification of PIV-1, PIV-2, PIV-3 and the PRC occurs using target-specific primers and fluorescent-labeled probes that hybridize to conserved regions in the genomes of PIV-1, PIV-2, PIV-3 and the PRC.

The Lyra Parainfluenza Virus assay has a convenient, one-step reagent set up performed at room temperature on the bench top, without the need for ice or other cooling accessories. Moreover, optimized cycling conditions make results available in less than 75 minutes following extraction to aid in timely diagnosis and treatment. Lyra Parainfluenza Virus RT-PCR is available for use on the Applied Biosystems®  7500 Fast Dx Real-Time PCR Instrument.

The Lyra Parainfluenza Virus assay provides the flexibility to customize respiratory panels with other Lyra Real-Time PCR respiratory assays (Lyra Influenza A+B, Lyra hMPV+RSV, Lyra Adenovirus) that are run under the same cycling conditions to adapt to the shifting demands caused by variable local or seasonal disease prevalence. 

Please see chart below for ordering information.

Contact us

Ordering information
Catalog numberDescriptionKit size / Case size
M114 Assay Kit 96 tests
M115 Quidel Molecular Parainfluenza Virus Control Set 10 reactions

 

Features & benefits

Rehydration solution is simply added to the lyophilized Master Mix for one-step reagent set-up.

Speedy results in less than 75 minutes after extraction.

Simplified and uniform workflow with standard pipetting volumes for easy training.

Find what you need

To access safety data sheets, package inserts, quick reference guides and all other technical and promotional materials, visit our technical documents library.

 

Technical documentation

Product specifications
Sample type Nasal swab, Nasopharyngeal swab
Time to results Less than 75 minutes after extraction
Reagent storage conditions 2°C to 8°C
Controls storage conditions 2°C to 8°C
Sensitivity* PIV-1: 100%; PIV-2:100%; PIV-3:100%
Specificity* PIV-1: 99.8%; PIV-2:100%; PIV-3:99.6%
Positive Percent Agreement* PIV-1: 100%; PIV-2:100%; PIV-3:100%
Negative Percent Agreement* PIV-1: 98.8%; PIV-2:94.0%; PIV-3:100%
LOD PIV-1: 2.50 x 100; PIV-2: 2.50 x 102; PIV-3:8.00 x 101 (TCID50/mL)
Sample volume needed for extraction 180 µL
Purified nucleic acid volume needed to testing 5 µL
Shelf life 24 months

 

*Refer to Package Insert for additional performance claims.

 

 

 

 

 

Workflow using the 7500 Series

s-card-img

D3® Double Duet DFA Respiratory Virus Screening & ID Kit

D3® Duet DFA Influenza A/Respiratory Virus Screening Kit

D3® Duet DFA RSV/Respiratory Virus Screening Kit

D3® Ultra 8TM DFA Respiratory Virus Screening and ID Kit

D3® Ultra 8TM DFA Individual Reagent Sets